● Pm tolasi bitta FC / APC va bitta FC / kompyuter ulagichi bilan
● to'lqin uzunligi 400 dan 2200 nm gacha
● Maxfiy ulagich va Uzunlik variantlari mavjud

Xususiyatlari
● Tor kalit (2,0 mm) sekin o'qga moslashtirilgan
● 1 db (FC / PC Ulagich) va 60 db (FC / APC ulagichi)
● APC ulagichida 8 daraja bog'lab qo'yilgan ferma
● ● Ø3 MM himoya tashqi ko'ylagi
parametr
| # Prefiks | P5 - 405bpm-fc | P5 - 488pm-FC | P5 - 630pm-FC | P5 - 780pm-FC | P5 - 980pm-fc |
|---|---|---|---|---|---|
| Tekislik to'lqin uzunligi | 405 nm | 488 nm | 635 nm | 780 nm | 980 nm |
| Tolali turlar | |||||
| Tola turi | PM - S405-XP (Panda) | PM460-HP (Panda) | PM630-HP (Panda) | PM780-HP (Panda) | PM980-XP (Panda) |
| To'lqin uzunligi | 400 - 680 nm nm | 460 - 700 nm nm | 620 - 850 nm nm | 770 - 1100 nm nm | 970 - 1550 nm nm |
| Mode maydoni diametria | 3.3 ± 0,5 mkm @ 405 nm | 3.3 ± 0,5 mkm @ 515 nm | 4.5 ± 0,5 mkm @ 630 nm | 5.3 ± 1.0 mkm @ 850 nm | 6.6 ± 0,5 mkm @ 980 nm |
| Raqamli teshigmab | 0.12 | 0.12 | 0.12 | 0.12 | 0.12 |
| Yamoq kabel xususiyatlari | |||||
| Qo'shish yo'qotishc,d | 1.50 db (max) 1.20 DB (TUZ.) |
1.50 db (max) 1.20 DB (TUZ.) |
1.2 db (max) 1.0 db (TUZ.) |
1.00 dB (max) 0.70 db (TUZ.) |
0.70 db (max) 0.50 db (TUZ.) |
| Yo'qolib ketish nisbatic,d | 15 dB (min) 17 db (TUZ.) |
18 db (min) 20 db (TUZ.) |
20 db (min) 22 db (TUZ.) |
20 db (min) 22 db (TUZ.) |
22 db (min) 24 db (TUZ.) |
| Optik qaytarish yo'qotishc | 50 db (tipik) @ fc / kompyuter ulagichi 60 db (tipik) @ FC / APC ulagichi |
||||
| Ulagich turi | 1 FC / PC, 1 FC / APC | ||||
| Kalit kengligi | 2.00 mm (tor kalit) | ||||
| Sekin o'qni tekislash | Ulagich kalitiga moslashtirilgane | ||||
| Kabel uzunligi | 1,0 m gacha bo'lgan mahsulot raqamlari uchun 1,0 m 2,0 m gacha bo'lgan mahsulot raqamlari uchun -2 5,0 m gacha 10,10-sonli mahsulot raqamlari uchun 10,0 m |
||||
| Kabel uzunlikdagi bag'rikenglik | +0.075/-0 m | ||||
| Pidjak turi | Ø3 mm ko'k pvc furcation | ||||
| Ishlash harorati | 0 dan 70 daraja | ||||
| Saqlash harorati | -45 dan 85 darajagacha | ||||
| # Prefiks | P5 - 1064pm-fc | P5 - 1310p-FC | P5 - 1550pm-fc | P5 - 2000pm-fc |
|---|---|---|---|---|
| Tekislik to'lqin uzunligi | 1064 nm | 1310 nm | 1550 nm | 2000 nm nm |
| Tolali turlar | ||||
| Tola turi | PM980-XP (Panda) | PM300-XP (Panda) | PM550-XP (Panda) | PM2000 (Panda) |
| To'lqin uzunligi | 970 - 1550 nm nm | 1270 - 1625 nm nm | 1440 - 1625 nm nm | 1850 - 2200 nm nm |
| Mode maydoni diametria | 6.6 ± 0,5 mkm @ 980 nm | 9.3 ± 0,5 mkm @ 1300 nm | 10.1 ± 0,4 mkm @ 1550 nm | 8,0 mkm @ 1950 nm |
| Raqamli teshigmab | 0.12 | 0.12 | 0.125 | 0.20 |
| Yamoq kabel xususiyatlari | ||||
| Qo'shish yo'qotishc,d | 0.70 db (max) 0.50 db (TUZ.) |
0.50 db (max) 0.30 db (TUZ.) |
0.50 db (max) 0.30 db (TUZ.) |
0.50 db (max) 0.30 db (TUZ.) |
| Yo'qolib ketish nisbatic,d | 22 db (min) 24 db (TUZ.) |
23 db (min) 25 db (TUZ.) |
23 db (min) 25 db (TUZ.) |
23 db (min) 25 db (TUZ.) |
| Optik qaytarish yo'qotishc | 50 db (tipik) @ fc / kompyuter ulagichi 60 db (tipik) @ FC / APC ulagichi |
|||
| Ulagich turi | 1 FC / PC, 1 FC / APC | |||
| Kalit kengligi | 2.00 mm (tor kalit) | |||
| Sekin o'qni tekislash | Ulagich kalitiga moslashtirilgane | |||
| Kabel uzunligi | 1,0 m gacha bo'lgan mahsulot raqamlari uchun 1,0 m 2,0 m gacha bo'lgan mahsulot raqamlari uchun -2 5,0 m gacha |
|||
| Kabel uzunlikdagi bag'rikenglik | +0.075/-0 m | |||
| Pidjak turi | Ø3 mm ko'k pvc furcation | |||
| Ishlash harorati | 0 dan 70 daraja | |||
| Saqlash harorati | -45 dan 85 darajagacha | |||
► Moddiy holat diametri (MFD) nominal qiymati sifatida ko'rsatilgan. Bu 1 / E da diametr2Yaqin sohada quvvat darajasi.
► Raqamli Apertasma (NA) nominal qiymati sifatida ko'rsatilgan.
► chizma to'lqin uzunligida o'lchanadi.
► O'lchov koeffitsientining minimal koeffitsientini va maksimal qismlarni yo'qotish texnika kabellari texnikani qo'llab-quvvatlash orqali mavjud.
► Shaxsiy tugmachalar uchun texnik yordam bilan bog'laning.
Issiq teglar: Pm gibrid yamoqli kabellar, Xitoy, zavod, etkazib beruvchilar, kotirovka, moslashtirilgan, narx, sotib olish